AI Diesel Tech

Fault Code Reference

SPN 4364 FMI 6AftertreatmentMedium

SCR NOx Efficiency Sensor - Current Above Normal

Scan Tool — in guided session

DVOM Testing — in guided session

Connector Pinout — in guided session

DieselVision™ Upload photos — DieselVision™ reads diagrams, connectors, and screens with precision.

Overview

Fault Code

SPN 4364 / FMI 6

Category

Aftertreatment

Severity

Medium

Derate Risk

Sometimes

Regen Inhibit

No

Inducement Risk

No

Component Location: Downstream NOx sensor is mounted in the exhaust outlet pipe exiting the SCR catalyst, typically at the rear of the aftertreatment assembly on the frame rail or tunnel.

Common Symptoms

  • Active fault code SPN 4364 FMI 6 logged in aftertreatment module
  • SCR NOx efficiency sensor circuit showing excessive current draw
  • Possible illumination of MIL or amber warning lamp
  • Reduced SCR system monitoring capability
  • Potential SCR catalyst efficiency faults triggered simultaneously
  • Possible inhibited or incomplete DEF dosing feedback

Root Causes

  • Short circuit to ground or battery voltage in NOx sensor signal or power circuit
  • Damaged or chafed wiring harness causing excessive current on sensor circuit
  • Failed downstream NOx sensor with internal short
  • Corroded or water-intruded sensor connector causing low-resistance path
  • Failed aftertreatment control module (ACM) output driver supplying sensor
  • Incorrect sensor installed causing impedance mismatch and overcurrent condition

Full step-by-step tests, DVOM guidance, and pinout data are available inside the AI Diesel Tech diagnostic session.

AI walks you through every test — one step at a time. Plans start at $12.95/mo.

Derate Behavior

Power Derate

Sometimes

Mileage / Regen Notes

Short circuit — inspect wiring before replacing sensor.

System Interactions

SPN 4364 FMI 6 interacts with the following systems and may trigger cascading faults if not resolved promptly.

DPF differential pressure monitoring — soot load calculations affected
SCR NOx conversion efficiency — DEF dosing strategy may be altered
Active regen inhibit logic — regen may be blocked or delayed
Engine protection derate — ECM may reduce power to protect components
TSB Reference: Efficiency sensor TSB

Common Diagnostic Mistakes

Replacing the sensor without verifying wiring continuity and supply voltage first.

Clearing codes without identifying and resolving the root cause — the fault will return.

Ignoring related active faults — cascading faults often share a root cause.

Skipping the connector inspection — corrosion and damaged pins are a leading cause of sensor faults.

Condemning the ECM before exhausting all wiring and component tests.

Replacing the DPF without verifying the regen system is functional — a failed regen injector will reload the new DPF.

Ignoring DEF quality — contaminated DEF causes SCR efficiency faults that look like hardware failures.

Deep-dive diagnostic page: SPN 4364 FMI 6 — Full FSM Sequence & Repair Steps — includes wiring notes, sensor specs, and gated repair procedures.

Get weekly diesel diagnostic tips

Real-world fault code walkthroughs, wiring tips, and shop-tested fixes — free.

No spam. Unsubscribe anytime.

Get AI-Guided Diagnosis for SPN 4364 FMI 6

The diagnostic engine walks you through every physical test — step by step, on your phone, at the truck. No guessing. No wasted parts.