AI Diesel Tech

Fault Code Reference

SPN 4364 FMI 3AftertreatmentMedium

SCR NOx Efficiency Sensor - Voltage High

Scan Tool — in guided session

DVOM Testing — in guided session

Connector Pinout — in guided session

DieselVision™ Upload photos — DieselVision™ reads diagrams, connectors, and screens with precision.

Overview

Fault Code

SPN 4364 / FMI 3

Category

Aftertreatment

Severity

Medium

Derate Risk

Sometimes

Regen Inhibit

No

Inducement Risk

No

Component Location: Downstream NOx sensor is mounted on the SCR outlet cone or exhaust pipe downstream of the SCR catalyst, typically toward the rear underside of the vehicle.

Common Symptoms

  • SCR NOx efficiency fault active in ECM
  • MIL or amber warning lamp illuminated
  • DEF system warning active
  • Possible inducement or derate condition
  • NOx sensor reading implausibly high or out of range

Root Causes

  • Failed or internally shorted downstream NOx sensor supplying voltage above sensor range Damaged or chafed wiring harness causing short to voltage on signal circuit Corroded or moisture-contaminated sensor connector Faulty NOx sensor heater circuit interaction causing signal voltage spike Failed NOx sensor control module or gateway ECU ECM internal fault on NOx sensor input circuit

Full step-by-step tests, DVOM guidance, and pinout data are available inside the AI Diesel Tech diagnostic session.

AI walks you through every test — one step at a time. Plans start at $12.95/mo.

Derate Behavior

Power Derate

Sometimes

Mileage / Regen Notes

Sensor circuit issue — check wiring before replacing sensor.

System Interactions

SPN 4364 FMI 3 interacts with the following systems and may trigger cascading faults if not resolved promptly.

DPF differential pressure monitoring — soot load calculations affected
SCR NOx conversion efficiency — DEF dosing strategy may be altered
Active regen inhibit logic — regen may be blocked or delayed
Engine protection derate — ECM may reduce power to protect components
TSB Reference: Efficiency sensor TSB

Common Diagnostic Mistakes

Replacing the sensor without verifying wiring continuity and supply voltage first.

Clearing codes without identifying and resolving the root cause — the fault will return.

Ignoring related active faults — cascading faults often share a root cause.

Skipping the connector inspection — corrosion and damaged pins are a leading cause of sensor faults.

Condemning the ECM before exhausting all wiring and component tests.

Replacing the DPF without verifying the regen system is functional — a failed regen injector will reload the new DPF.

Ignoring DEF quality — contaminated DEF causes SCR efficiency faults that look like hardware failures.

Deep-dive diagnostic page: SPN 4364 FMI 3 — Full FSM Sequence & Repair Steps — includes wiring notes, sensor specs, and gated repair procedures.

Get weekly diesel diagnostic tips

Real-world fault code walkthroughs, wiring tips, and shop-tested fixes — free.

No spam. Unsubscribe anytime.

Get AI-Guided Diagnosis for SPN 4364 FMI 3

The diagnostic engine walks you through every physical test — step by step, on your phone, at the truck. No guessing. No wasted parts.