AI Diesel Tech

Fault Code Reference

SPN 4360 FMI 6AftertreatmentMedium

SCR Intake Gas Temperature Sensor - Current Above Normal

Scan Tool — in guided session

DVOM Testing — in guided session

Connector Pinout — in guided session

DieselVision™ Upload photos — DieselVision™ reads diagrams, connectors, and screens with precision.

Overview

Fault Code

SPN 4360 / FMI 6

Category

Aftertreatment

Severity

Medium

Derate Risk

Sometimes

Regen Inhibit

No

Inducement Risk

No

Component Location: SCR intake gas temperature sensor is mounted on the exhaust pipe upstream of the SCR catalyst brick, typically near the diesel oxidation catalyst outlet or SCR inlet cone.

Common Symptoms

  • Erratic SCR inlet temp reading

Root Causes

  • Short circuit to ground or voltage in SCR intake temperature sensor signal wire causing excessive current draw Damaged or chafed wiring harness between SCR intake temperature sensor and aftertreatment control module Faulty SCR intake gas temperature sensor with internal short circuit Corroded or moisture-contaminated sensor connector causing low resistance path and high current Pinched wiring harness near aftertreatment system causing insulation breakdown Failed aftertreatment control module (ACM/DCU) with shorted sensor supply or signal circuit Incorrect sensor installed (wrong resistance/type) causing abnormal current levels

Full step-by-step tests, DVOM guidance, and pinout data are available inside the AI Diesel Tech diagnostic session.

AI walks you through every test — one step at a time. Plans start at $12.95/mo.

Derate Behavior

Power Derate

Sometimes

Mileage / Regen Notes

Short circuit — inspect wiring before replacing sensor.

System Interactions

SPN 4360 FMI 6 interacts with the following systems and may trigger cascading faults if not resolved promptly.

DPF differential pressure monitoring — soot load calculations affected
SCR NOx conversion efficiency — DEF dosing strategy may be altered
Active regen inhibit logic — regen may be blocked or delayed
Engine protection derate — ECM may reduce power to protect components

Common Diagnostic Mistakes

Replacing the sensor without verifying wiring continuity and supply voltage first.

Clearing codes without identifying and resolving the root cause — the fault will return.

Ignoring related active faults — cascading faults often share a root cause.

Skipping the connector inspection — corrosion and damaged pins are a leading cause of sensor faults.

Condemning the ECM before exhausting all wiring and component tests.

Replacing the DPF without verifying the regen system is functional — a failed regen injector will reload the new DPF.

Ignoring DEF quality — contaminated DEF causes SCR efficiency faults that look like hardware failures.

Deep-dive diagnostic page: SPN 4360 FMI 6 — Full FSM Sequence & Repair Steps — includes wiring notes, sensor specs, and gated repair procedures.

Get weekly diesel diagnostic tips

Real-world fault code walkthroughs, wiring tips, and shop-tested fixes — free.

No spam. Unsubscribe anytime.

Get AI-Guided Diagnosis for SPN 4360 FMI 6

The diagnostic engine walks you through every physical test — step by step, on your phone, at the truck. No guessing. No wasted parts.