AI Diesel Tech

Fault Code Reference

SPN 3714 FMI 31AftertreatmentInducement Risk

Aftertreatment 1 DEF Dosing Absolute Pressure - Condition Exists

Scan Tool — in guided session

DVOM Testing — in guided session

Connector Pinout — in guided session

DieselVision™ Upload photos — DieselVision™ reads diagrams, connectors, and screens with precision.

Overview

Fault Code

SPN 3714 / FMI 31

Category

Aftertreatment

Derate Risk

Yes

Regen Inhibit

No

Inducement Risk

Yes — SCR inducement possible

Component Location: DEF supply module (pump) and dosing injector located near the DEF tank or along the chassis frame rail, connected by insulated supply and return lines to the SCR module.

Common Symptoms

  • Check engine light illuminated
  • DEF system malfunction warning
  • Engine derate or power reduction
  • DEF dosing performance issues
  • Inducement warning or countdown timer active
  • Poor NOx conversion efficiency

Root Causes

  • DEF supply module (pump) failure causing abnormal pressure readings Clogged or restricted DEF filter/strainer reducing supply pressure DEF injector clogged or stuck open/closed affecting system pressure Air ingestion into DEF supply lines causing pressure anomalies DEF quality issue (diluted or contaminated fluid) affecting pump performance DEF tank level critically low causing pump cavitation DEF supply line leak or loose fitting causing pressure loss ACM software fault or calibration mismatch triggering condition exists code DEF pressure sensor failure or drift Frozen DEF lines or injector in cold weather conditions

Full step-by-step tests, DVOM guidance, and pinout data are available inside the AI Diesel Tech diagnostic session.

AI walks you through every test — one step at a time. Plans start at $12.95/mo.

Derate Behavior

Power Derate

Yes

SCR Inducement Risk

If left unresolved, this fault may trigger SCR inducement — a progressive derate enforced by the ECM to ensure emissions compliance.

System Interactions

SPN 3714 FMI 31 interacts with the following systems and may trigger cascading faults if not resolved promptly.

DPF differential pressure monitoring — soot load calculations affected
SCR NOx conversion efficiency — DEF dosing strategy may be altered
Active regen inhibit logic — regen may be blocked or delayed
Engine protection derate — ECM may reduce power to protect components

Common Diagnostic Mistakes

Replacing the sensor without verifying wiring continuity and supply voltage first.

Clearing codes without identifying and resolving the root cause — the fault will return.

Ignoring related active faults — cascading faults often share a root cause.

Skipping the connector inspection — corrosion and damaged pins are a leading cause of sensor faults.

Condemning the ECM before exhausting all wiring and component tests.

Replacing the DPF without verifying the regen system is functional — a failed regen injector will reload the new DPF.

Ignoring DEF quality — contaminated DEF causes SCR efficiency faults that look like hardware failures.

Deep-dive diagnostic page: SPN 3714 FMI 31 — Full FSM Sequence & Repair Steps — includes wiring notes, sensor specs, and gated repair procedures.

Get weekly diesel diagnostic tips

Real-world fault code walkthroughs, wiring tips, and shop-tested fixes — free.

No spam. Unsubscribe anytime.

Get AI-Guided Diagnosis for SPN 3714 FMI 31

The diagnostic engine walks you through every physical test — step by step, on your phone, at the truck. No guessing. No wasted parts.