AI Diesel Tech

Fault Code Reference

SPN 3248 FMI 4AftertreatmentMedium

Aftertreatment 1 SCR Inlet Temperature — Voltage Below Normal

Scan Tool — in guided session

DVOM Testing — in guided session

Connector Pinout — in guided session

DieselVision™ Upload photos — DieselVision™ reads diagrams, connectors, and screens with precision.

Overview

Fault Code

SPN 3248 / FMI 4

Category

Aftertreatment

Fault Type

sensor

FMI Category

voltage low

Severity

Medium

Derate Risk

No

Regen Inhibit

No

Inducement Risk

No

Component Location: SCR inlet temperature sensor — on exhaust pipe upstream of SCR

Common Symptoms

  • SCR inlet temp sensor reading low
  • DEF dosing affected
  • SCR efficiency monitoring unavailable

Root Causes

  • Sensor open circuit
  • Wiring open circuit
  • Sensor failed

Full step-by-step tests, DVOM guidance, and pinout data are available inside the AI Diesel Tech diagnostic session.

AI walks you through every test — one step at a time. Plans start at $12.95/mo.

Derate Behavior

Power Derate

No

Mileage / Regen Notes

Open circuit faults common at 200k–350k miles.

System Interactions

SPN 3248 FMI 4 interacts with the following systems and may trigger cascading faults if not resolved promptly.

DPF differential pressure monitoring — soot load calculations affected
SCR NOx conversion efficiency — DEF dosing strategy may be altered
Active regen inhibit logic — regen may be blocked or delayed
Engine protection derate — ECM may reduce power to protect components
TSB Reference: Cummins TSB 4021941 — SCR Inlet Temperature Sensor Open Circuit

Common Diagnostic Mistakes

Replacing the sensor without verifying wiring continuity and supply voltage first.

Clearing codes without identifying and resolving the root cause — the fault will return.

Ignoring related active faults — cascading faults often share a root cause.

Skipping the connector inspection — corrosion and damaged pins are a leading cause of sensor faults.

Condemning the ECM before exhausting all wiring and component tests.

Replacing the DPF without verifying the regen system is functional — a failed regen injector will reload the new DPF.

Ignoring DEF quality — contaminated DEF causes SCR efficiency faults that look like hardware failures.

OEM Notes

Cummins

X15: Check harness routing near SCR.

Detroit

DD15: Check connector for moisture.

PACCAR

MX-13: Inspect connector boot.

Deep-dive diagnostic page: SPN 3248 FMI 4 — Full FSM Sequence & Repair Steps — includes wiring notes, sensor specs, and gated repair procedures.

Get weekly diesel diagnostic tips

Real-world fault code walkthroughs, wiring tips, and shop-tested fixes — free.

No spam. Unsubscribe anytime.

Get AI-Guided Diagnosis for SPN 3248 FMI 4

The diagnostic engine walks you through every physical test — step by step, on your phone, at the truck. No guessing. No wasted parts.