AI Diesel Tech

Fault Code Reference

SPN 4363 FMI 2Medium

SCR Outlet Temperature - Data Erratic

Scan Tool — in guided session

DVOM Testing — in guided session

Connector Pinout — in guided session

DieselVision™ Upload photos — DieselVision™ reads diagrams, connectors, and screens with precision.

Overview

Fault Code

SPN 4363 / FMI 2

Severity

Medium

Regen Inhibit

No

Inducement Risk

No

Component Location: SCR outlet temperature sensor is mounted in the exhaust outlet pipe immediately downstream of the SCR catalyst brick, typically on the rear or underside of the aftertreatment assembly.

Common Symptoms

  • SCR outlet temperature reading erratic or fluctuating abnormally
  • Active fault code logged for SPN 4363 FMI 2
  • Aftertreatment system inhibiting or interrupting DEF dosing
  • DPF regeneration inhibited or interrupted
  • SCR efficiency faults triggered secondary to unstable temp signal
  • Intermittent or stuck temperature reading on scan tool data

Root Causes

  • Damaged, corroded, or loose connector at SCR outlet temperature sensor
  • Failed or failing SCR outlet temperature sensor (thermistor degradation)
  • Chafed, shorted, or open wiring harness between sensor and ACM/ECM
  • Moisture or contamination intrusion into sensor connector
  • Poor ground reference at sensor or aftertreatment control module
  • Aftertreatment Control Module (ACM) internal fault causing erratic signal interpretation
  • Exhaust soot or chemical contamination on sensor tip affecting thermal response

Full step-by-step tests, DVOM guidance, and pinout data are available inside the AI Diesel Tech diagnostic session.

AI walks you through every test — one step at a time. Plans start at $12.95/mo.

Derate Behavior

Mileage / Regen Notes

Erratic SCR outlet temperature signal may inhibit active DPF regeneration initiation or cause an in-progress regen to be aborted, as the ACM relies on this signal to confirm safe exhaust temperatures downstream of the SCR catalyst.

System Interactions

SPN 4363 FMI 2 interacts with the following systems and may trigger cascading faults if not resolved promptly.

TSB Reference: SCR temp TSB

Common Diagnostic Mistakes

Replacing the sensor without verifying wiring continuity and supply voltage first.

Clearing codes without identifying and resolving the root cause — the fault will return.

Ignoring related active faults — cascading faults often share a root cause.

Skipping the connector inspection — corrosion and damaged pins are a leading cause of sensor faults.

Condemning the ECM before exhausting all wiring and component tests.

Deep-dive diagnostic page: SPN 4363 FMI 2 — Full FSM Sequence & Repair Steps — includes wiring notes, sensor specs, and gated repair procedures.

Get weekly diesel diagnostic tips

Real-world fault code walkthroughs, wiring tips, and shop-tested fixes — free.

No spam. Unsubscribe anytime.

Get AI-Guided Diagnosis for SPN 4363 FMI 2

The diagnostic engine walks you through every physical test — step by step, on your phone, at the truck. No guessing. No wasted parts.